Product Details:
Payment & Shipping Terms:
|
Material: | Rebar | Wire Diameter: | 3.0 Mm |
---|---|---|---|
Mesh: | 150 X 150 Mm | Surface Finish: | Nature |
Hole Shape: | Square | Size: | 2 X 100m |
Wire Gauge: | 2.0-4.0mm | Application: | Construction Wire Mesh,building,bridge,garden Fence |
Type: | Welded Mesh,Electric Wire Mesh,Panel Or Roll | Aperture: | 3/4" X 3/4" 3/8"x3/8" 1" X 1'' |
Surface Treatment: | Hot Dipped Galvanized,pvc Coated,galvanized/pvc Coated,powder Coated | Width: | 300mm-2500mm,0.5m To 2.2m |
Length: | 30m,50m,10m,5m,25m | Usage: | Protection,building,Agriculture,construction,garden |
Packing: | Waterproof Paper,Pallet,in Bulk,In Roll,Panel | Product Name: | Welded Wire Mesh,Galvanized / PVC Coated Welded Wire Mesh,F82 Reinforcing Mesh |
Color: | Green,Grey,or As Request | Feature: | Easily Assembled,lacquer,Waterproof,Anti-rust,Anti-corrosion |
Highlight: | welded wire panels,welded wire fabric |
Reinforcing Mesh is used for the reinforcement of concrete, is manufactured to SANS 1024:2006 and to other international standard specifications.
Features:
Important design criteria
Placing of Fabric
In order to obtain the best results when using fabric reinforcement, special care must be taken to ensure that the mesh is positioned and maintained at the correct depth after the concrete pour. This can be done by using stools or plastic or concrete spacers. Another option is to place the fabric on poured concrete that has been leveled to the desired reinforcement depth. After placing the mesh the concrete can be topped up to the specified overall slab thickness.
Ideally fabric must be located 50 mm from the top of the slab and where bottom steel is required, it must also be supported 50 mm above the substrate.
Lapping of Fabric Mats
It is recommended that in calculating the lap requirement for surface bed welded mesh fabric reinforcement that the formula shall be 25 × diameter + 150 mm or 300 mm, whichever is the greatest.
Quality
The Reinforcing Mesh is manufactured under strict quality controls with all standards conforming to SANS 1024:2006 standard specifications and tolerances and carries the certification mark.
STRUCTURAL FABRIC REINFORCEMENT DESIGN DATA
Cross sectional areas at various spacing mm2/m
Mass at various spacing kg/m²
Diam | Area | Mass | Wire Spacing (Millimeters) | |||||||||||
mm | mm² | kg/m | 50 | 75 | 100 | 125 | 150 | 175 | 200 | 225 | 250 | 275 | 300 | |
12 | 113.11 | 2262 | 1508 | 1131 | 905 | 754 | 646 | 566 | 503 | 452 | 411 | 377 | 12 | |
0.888 | 17.76 | 11.84 | 8.88 | 7.10 | 5.92 | 5.07 | 4.44 | 3.95 | 3.55 | 3.23 | 2.96 | |||
11 | 95.05 | 1901 | 1267 | 950 | 760 | 634 | 543 | 475 | 422 | 380 | 346 | 317 | 11 | |
0.746 | 14.92 | 9.95 | 7.46 | 5.97 | 4.97 | 4.26 | 3.73 | 3.32 | 2.98 | 2.71 | 2.49 | |||
10 | 78.55 | 1571 | 1047 | 786 | 628 | 524 | 449 | 393 | 349 | 314 | 286 | 262 | 10 | |
0.617 | 12.34 | 8.23 | 6.17 | 4.94 | 4.11 | 3.53 | 3.09 | 2.74 | 2.47 | 2.24 | 2.06 | |||
9 | 63.63 | 1273 | 848 | 636 | 509 | 424 | 364 | 318 | 283 | 255 | 231 | 212 | 9 | |
0.500 | 10.00 | 6.67 | 5.00 | 4.00 | 3.33 | 2.86 | 2.50 | 2.22 | 2.00 | 1.82 | 1.67 | |||
8 | 50.27 | 1005 | 670 | 503 | 402 | 335 | 287 | 251 | 223 | 201 | 183 | 168 | 8 | |
0.395 | 7.90 | 5027 | 3.95 | 3.16 | 2.63 | 2.26 | 1.98 | 1.76 | 1.58 | 1.44 | 1.32 | |||
7.1 | 39.60 | 792 | 528 | 396 | 317 | 264 | 226 | 198 | 176 | 158 | 144 | 132 | 7.1 | |
0.311 | 6.22 | 4.15 | 3.11 | 2.49 | 2.07 | 1.78 | 1.56 | 1.38 | 1.24 | 1.13 | 1.04 | |||
6.3 | 31.18 | 624 | 416 | 312 | 249 | 208 | 178 | 156 | 139 | 125 | 113 | 104 | 6.3 | |
0.245 | 4.90 | 3.27 | 2.45 | 1.96 | 1.63 | 1.40 | 1.23 | 1.09 | 0.98 | 0.89 | 0.82 | |||
5.6 | 24.63 | 493 | 328 | 246 | 197 | 164 | 141 | 123 | 109 | 99 | 90 | 82 | 5.6 | |
0.193 | 3.86 | 5.57 | 1.93 | 1.54 | 1.29 | 1.10 | 0.97 | 0.86 | 0.77 | 0.70 | 0.64 | |||
4 | 12.57 | 251 | 168 | 126 | 101 | 84 | 72 | 63 | 56 | 50 | 46 | 42 | 4 | |
0.100 | 2.00 | 1.33 | 1.00 | 0.80 | 0.67 | 0.57 | 0.50 | 0.44 | 0.40 | 0.36 | 0.33 |
Contact Person: Mr. Devin Wang
Fax: 86-318-7896133